    The FT94X service unit contains the services, controls and

    instrumentation required to operate the tubular and plate heat exchangers described below. The FT94X may be specified with either or both of the heat exchangers. Switching between the two heat exchangers takes a matter of seconds.

    The service unit comprises: an eight inch touch screen control panel with the required controls and displays; a variable speed progressive cavity product feed pump with inlet level sensor and alarm to warn of low product level; a steam-heated hot water system for product preheating; automatic steam control valves for product preheating and final heating; a centrifugal CIP pump and other facilities required for CIP and SIP.

    Sensors show product inlet, preheat, final heating and outlet temperatures. Product preheat and final heating temperatures are set by the operator. Inlet and outlet product pressure is also shown.

    There are various service sensors: pressure, level and temperature – see process flow diagram for details.

    A sophisticated data logging package enables the measured data to be recorded onto a standard Windows PC (not supplied).

    The software records all temperatures, product and steam pressures, feed pump speed and many other sensor values. Data from optional accessories (e.g. the flowmeter) is also recorded. Data may be displayed in tables and graphs (both real time and comparisons across previous runs), and may also be exported to MS Excel.


    The FT94-20 is a standard tubular heat exchanger design

    using a series of concentric 316 stainless steel tubes for product preheating, final heating and cooling. In all cases the product passes down the inner tube and the heating/cooling medium passes through the annulus. Two heating tubes of 1.5 m length are used to preheat the product. Four similar tubes are used for product heating and an additional four tubes are used for product cooling.

    Product is gently preheated using a hot water system, which is itself heated by steam via a secondary service heat exchanger. In the main heating section the product is indirectly heated using steam itself.

    Product is cooled normally using water or chilled water. The cooling section can be configured to enable two stages where the first stage is water/chilled water and the second stage is water/glycol.

    The FT94-21 is a set of static mixers for two tubes. These significantly improve heat transfer with more viscous products and can be used for improving both heating and cooling efficiency. Multiple sets can be used to optimise both heating and cooling performance.

    The FT94-22 product divert option enables product that has not been processed to a sufficiently high temperature to be diverted to drain thus ensuring product quality and heat treatment.

    The divert temperature is adjustable. Diversion is achieved using a low hold-up twin diaphragm valve block operated by compressed air and PLC controlled. Diverted product is cooled in a tubular heat exchanger before being led to drain.

    The FT94-20 has a one second holding tube (at 50 l/hr) as standard. Contact Armfield for longer holding times.


    The FT94-30 uses the sanitary heat exchanger employing the

    latest plate design for efficient heat transfer. Performance scale-up is straight forward. The standard unit is a three stage system with preheat (hot water) final heating (steam) and cooling (water/chilled water).

    The plates have a complex pressed profile to maximise turbulence

    and minimise dead zones. There is a relatively large gap between plates to enable handling of more viscous products. The plates are fitted with food grade Viton paraclip gaskets for easy replacement as these are simply clipped in place rather than glued.

    A number of options are available to enhance the performance of the standard plate heat exchanger. These options involve additional plate configurations, which can be supplied and fitted or may be easily retro-fitted by the user.

    The FT94-32 homogeniser interconnecting plate enables the homogeniser to be connected downstream of the heating section. The plate is fitted into the cooling section.

    The FT94-33 two-stage cooling option provides a complete additional cooling stage, which can be used in conjunction with

    a chilled water/glycol supply for the best possible product cooling. Output temperatures below 5°C are possible depending on the product and the flow rate.

    An interconnecting link is provided so that the two stages can be operated as a single stage when required.

    The FT94-30 has a five second holding tube (at 50 l/hr) as standard. Contact Armfield for longer holding times.




    Technical specifications                                                                                                                                      

    FT94X Service Unit Technical specifications

    Tubular Heat Exchanger (FT94-20)

    Feed pump

    Number of tubes

    10 (2 preheat, 4 heating, 4 cooling)

    Progressive cavity variable speed pump

    Tube diameter

    Solids handling

    Soft 10 mm

    (product side)

    8.1 mm

    Hard 4 mm

    Overall diameter

    22.0 mm

    Flow rate

    30-100 l/hr

    Length (heated)

    1.46 m

    Discharge pressure

    24 bar (max)

    Product volume

    1.0 l

    Pre-heat water system

    Material

    316 stainless steel

    Water capacity

    ~2-3 litres

    Assembled test pressure

    30 bar

    Maximum temp

    110°C

    Working pressure

    24 bar (maximum)

    Safety cut-outs

    Low level

    Plate Heat Exchanger (FT94-30)

     

    Temperature

    Plate overall dimensions

    150 x 480mm

     

    Product pump

    Effective area per plate

    0.04m2

     

    Pressure relief valve

    Plate thickness

    0.6mm

    Heating system

    Product volume

    2.5litres

    External steam supply

     

    Materials,Plates

    316 stainless steel

    Maximum temp

    165°C

    Gaskets

    Food grade Viton

     

    Relief valve (7 barg)

    Max differential test pressure

    11.5bar

     

    Product pump off

    Max balanced test pressure

    12.5bar

     

    steam valve closes

    Max working pressure

    9.6bar

    Max product heating duty

    17 kW

    Working temperature

    Max: 170°C

     

    (preheat + heating)

     

    Min: -4°C

     

     

    Number of plates

     

     

    FT94-30

    Preheating 13, Heating 6, Cooling 13

     

     

    FT94-33

    Secondary cooling 7





    Project Case
    Solution
    Download
    相关标签